PULSE=DISABLE_SINGLE_PULSE, SYNCH=DISABLE__SYNCHRONIZ, EDGE=NO_EDGE_DETECTION, INV=NOT_INVERTED, SELECT=CTOUT_8_OR_T2_MAT0
ADC start1 input multiplexer (GIMA output 29)
INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
SELECT | Select input. Values 0x2 to 0xF are reserved. 0 (CTOUT_8_OR_T2_MAT0): CTOUT_8 or T2_MAT0 1 (T2_MAT0): T2_MAT0 |
RESERVED | Reserved |